Development and validation of a reliable method for studying the distribution pattern for opiates metabolites in brain

2012

Abstract Brain distribution pattern of “street” heroin metabolites (morphine and codeine) was investigated in two fatalities due to “acute narcotism”. A suitable sample pretreatment prior to solid-phase-extraction was developed to achieve a good recovery of the analytes and to eliminate the interfering species. After derivatization with MSTFA, samples were analyzed by GC/MS. Specificity, accuracy, precision and linearity of the method were evaluated; LOD and LOQ were, respectively, 10 ng/25 ng for morphine and 5 ng/10 ng for codeine. This method was applied to the analysis of six brain areas (hippocampus, frontal lobe, occipital lobe, nuclei, bulb and pons) coming from two cases of heroin-r…

AdultMaleClinical BiochemistryAnalytical chemistryPharmaceutical ScienceHippocampusGas Chromatography-Mass SpectrometryAnalytical ChemistryHeroinchemistry.chemical_compoundSettore MED/43 - Medicina LegaleLimit of DetectionDrug DiscoverymedicineHumansTissue DistributionDerivatizationSpectroscopyHeroin; Morphine; Codeine; Post-mortem brain specimenChromatographyMolecular StructureMorphineCodeineHeroin DependenceIllicit DrugsCodeineBrainReproducibility of ResultsPonsHeroinSubstance Abuse DetectionchemistryFrontal lobeMorphinePost-mortem brain specimenDrug OverdoseOccipital lobemedicine.drug
researchProduct

A human post-mortem brain model for the standardization of multi-centre MRI studies

2015

Multi-centre MRI studies of the brain are essential for enrolling large and diverse patient cohorts, as required for the investigation of heterogeneous neurological and psychiatric diseases. However, the multi-site comparison of standard MRI data sets that are weighted with respect to tissue parameters such as the relaxation times (T1, T2) and proton density (PD) may be problematic, as signal intensities and image contrasts depend on site-specific details such as the sequences used, imaging parameters, and sensitivity profiles of the radiofrequency (RF) coils. Water or gel phantoms are frequently used for long-term and/or inter-site quality assessment. However, these phantoms hardly mimic t…

Models Anatomicmedicine.medical_specialtyNeurologyCognitive NeuroscienceModels NeurologicalMulti-centre MRI studies; Post-mortem brain; Quantitative MRI; Standardization; Aged; Artifacts; Brain; Female; Humans; Magnetic Resonance Imaging; Multicenter Studies as Topic; Phantoms Imaging; Reproducibility of Results; Models Anatomic; Models Neurological; Postmortem Changes; Cognitive Neuroscience; Neurology; Medicine (all)Cognitive neuroscienceImaging phantomPhantomsImagingWhite matterModelsPost-mortem brainmedicineHumansMulticenter Studies as TopicMagnetization transferMulti-centre MRI studiesAgedmedicine.diagnostic_testbusiness.industryPhantoms ImagingMedicine (all)AnatomicBrainReproducibility of ResultsMagnetic resonance imagingHuman brainQuantitative MRIMagnetic Resonance ImagingStandardizationmedicine.anatomical_structureNeurologyPostmortem ChangesNeurologicalFemaleBrainstemNuclear medicinebusinessArtifacts
researchProduct